Option |
Function |
Value or range |
Description |
0 |
- |
- |
Unknown. |
General Operations |
1 |
Interface |
0..5 |
Interface speed after
power-up or reset. |
0* |
2400 bps. |
1 |
4800 bps. |
2 |
9600 bps. |
3 |
19200 bps. Recommended
setting. |
4 |
38400 bps. This speed is
not selectable with the 'Interface/Bit per second' menu, but the value '4'
and the 'XB38400' command are accepted, and the Intellibox works usually fine
at this speed. |
5 |
16457 bps. For
compatibility with Digitrax MS-100. LocoNet mode works also fine at other
speeds (preferrably 19200 or 38400). |
2 |
Interface |
0..4 |
Interface protocol
selected at startup or after reset. |
0* |
P50 protocol only. |
1 |
P50X protocol only. |
2 |
Both P50 and P50X
protocols (this is the so called 'mixed P50/P50X' protocol mode). |
3 |
Selectable with
'Interface/Syntax' menu, but not a valid option. |
4 |
LocoNet protocol. |
3 |
- |
- |
Unknown. |
4 |
Interface |
0..2 |
CTS signal polarity. |
0* |
Positive: +12V means
CTS=TRUE (PC class of computers). |
1 |
Negative: -12V means
CTS=TRUE (MAC class of computers). |
2 |
None: RS232 interface
disabled. |
5 |
Interface |
1..2 |
Number of stop bits used
by the Interface. |
Before version 1.500 2 stopbits were mandatory,
but now all protocols will work with either 1 or 2 stopbits. |
1 |
Recommended setting when
(sometimes) using software written exclusively for MS-100 or LocoBuffer. |
2* |
Default,
see also Long RS-232 Break. |
6 |
Interface |
0..255 |
CTS timing with power-off
('stop'). |
The use of CTS for flow control is
independent of the setting of this SO. |
0 |
CTS will go false
permanently with non computer induced track power-off condition (e.g.
short-circuit, push of a stop button). |
1..254* |
CTS will be false for the
specified time in units of 50 ms after a stop button has been pushed. Default
12.7 secs. |
255 |
CTS will never become
false due to pushing of a stop button. |
7 |
Interface |
80..95 |
Lead-In character for
P50X protocol (when in mixed P50/P50X mode). |
88* |
Default: 'X'. |
8 |
auto S88
reading |
0..62 |
Number of groups of 8
sensor-bits (half S88) to be read automatically. |
16* |
Default: 8 S88s with 16
contacts each. |
9 |
- |
- |
Unknown. |
10 |
Loc protocol |
0..8 |
Protocol used by all loc
decoders. May be overridden by individual loc specification. |
0 |
Motorola Old. |
1* |
Motorola New. |
2 |
DCC 14. |
3 |
DCC 27. |
4 |
DCC 28. |
5 |
DCC 28 DAC. |
6 |
DCC 128. |
7 |
DCC 128 DAC. |
8 |
Selectrix |
11 |
Warm start |
30..100 |
Time in units of 50 ms
that 'Go' and 'Stop' keys must be pressed together before a 'Reset' (warm
start cycle) is initiated. |
50* |
Default: 2.5 secs. |
12 |
Turnout protocol |
0..8 |
Protocol used by all
turnout decoders. May be overridden by individual turnout specification. |
0* |
Motorola protocol. |
1 |
DCC protocol. |
2..8 |
Unknown. |
13 |
Minimum
Turnout
Time |
0..255 |
Mimimum time in units of 50 ms that a
turnout must be kept powered on, even when another turnout command arrives. |
2* |
Default: 100 msecs. |
14 |
Maximum
Turnout
Time |
0..255 |
Maximum time in units of 50 ms that a
turnout must be left powered on, when no other turnout command arrives. |
100* |
Default: 5 secs. |
15 |
Track
voltage |
0 |
N-scale voltage. |
1* |
H0-scale voltage. |
16 |
Programming
Track |
0 |
Programming Track only
(relay always turned on). |
Programming track carries only programming
signal. |
1* |
Programming Track
automatic. Relay turned on when entering programming mode (from Intellibox
panel or computer). |
When not in programming mode the programming
track carries the same digital signal as the running track. |
17..18 |
- |
- |
Unknown. |
19 |
Loc status
restore |
0* |
Do not restore loc status
at physical power on or after a reset with X@, X@@ command or with go + stop
buttons. See also SO#31. |
1 |
Restore loc status, dir
and F1..4, but set speed to zero. |
2 |
Restore complete loc
status, incl. speed. |
20 |
P50
Loc
control |
0 |
P50 loc commands will be
discarded when loc is controlled manually (Märklin 6050 emulation). |
1* |
P50 loc commands will
override manual loc control. |
2..40 |
Unknown. |
21 |
P50
Turnout
control |
0* |
P50 turnout commands will be
discarded when Intellibox is in stop state (Märklin 6050 emulation). |
1 |
P50 turnout commands will
buffered when the Intellibox is in stop state and will be executed after
pressing 'Go'. |
About 16 turnout commands can be buffered. |
22 |
Idle
signal |
0..21 |
Number of idle packets
sent during power-on. |
When set to an odd number the value
applies to both Märklin and DCC protocol, when set to an even number it
applies only to Märklin/Motorola protocol. See also SO#907. |
0 |
DCC only protocol. |
6 |
Märklin only protocol. |
7* |
Mixed Märklin and DCC
protocol. |
23 |
S88
timers |
0 |
Contact timing not
active. |
1*..62 |
Sequence number of the
group of 8 sensor bits (half S88) for which timing information is provided. |
24 |
S88
counters |
0 |
Contact counting not
active. |
1*..62 |
Sequence number of the
group of 8 sensor bits (half S88) for which contact make counts are provided. |
25 |
Idle
signal |
0..15 |
Control of digital
signals on the rails (bitmask). |
bit 0 |
0 - send no DCC signal,
unless a DCC loc is active. |
1 - always send a DCC signal (Idle-signal
when no DCC loc active). |
bit 1 |
0 - send no Motorola
signal, unless a Motorola loc is active. |
1 - always send a Motorola signal
(Idle-signal when no Motorola loc active). |
bit 2 |
0 - send no Selectrix
signal, unless a Selectrix loc is active. |
1 - always send a Selectrix signal
(Idle-signal when no Selectrix loc active). |
bit 3 |
0 - send no ZZZ signal,
unless a ZZZ loc is active. |
1 - always send a ZZZ signal (Idle-signal
when no ZZZ loc active). |
26 |
Interface speed |
0 |
A 'long RS232 break' from
the computer does not affect the Interface speed. |
1* |
A 'long RS232 break' from
the computer resets the Interface speed to 2400 bps. |
27 |
Refresh cycle |
0 |
Never remove a loc from
refresh cycle once it is activated. |
1..240 |
Minimum time in minutes
between the last command to a loc and the moment it may be removed from the
refresh cycle. |
2* |
Default: two minutes. |
28 |
Refresh cycle |
0* |
Remove loc from refresh
cycle only when its speed is currently zero. |
1 |
May remove loc from
refresh cycle even when its current speed is not zero. |
29 |
Refresh cycle |
0 |
Do not remove loc from
refresh cycle when 'in-use'. |
1* |
May remove loc from
refresh cycle even when 'in-use'. |
30 |
- |
- |
Unknown. |
31 |
Power off |
0* |
Do not save the status of
locs which are not refreshed anymore. |
1 |
Save status of locs even
when not anymore in the refresh cycle but still 'in-use'. |
Use this value when locs with 'new' Märklin
decoders (like 60901) sometimes start in the wrong direction. |
32 |
- |
- |
Unknown. |
33 |
I2C echo |
0 |
Do not echo turnout commands on
the internal I2C bus. |
Recommended setting when no Märklin keyboards
or similar devices are connected to the Intellibox. |
1* |
Echo turnout commands on
the I2C bus. |
34..35 |
- |
- |
Unknown. |
36 |
Booster control |
1..200 |
Period after startup of
the IB (or from 'stop' to 'go') during which the Intellibox will ignore a
short-circuit signal from a booster in units of 10 ms. |
20* |
Default (200 ms). |
21 |
(or somewhat higher)
Overcome false Märklin 6017 booster short-circuit signal. |
37 |
I2C pause |
75..200 |
Pause time in ms between
VI2CL = +V and Go-line = high. |
150* |
Default: 0.15 secs. |
38 |
I2C pause |
75..200 |
Pause time in ms between
Go-line = high and start of C80(f) numbering procedure (LIPU). |
100* |
Default: 0.1 secs. |
39 |
Consist control |
0* |
Do not proliferate the
functions settings of the top loc of a consist to other locs of this consist. |
1 |
Copy function settings
for the top loc only to other locs of this consist with an odd address. |
2 |
Copy function commands
for the top loc only to other locs of this consist with an even address. |
3 |
Copy the function
settings of the top loc to all other locs of this consist. |
40..52 |
- |
- |
Unknown. |
53 |
Loc protocol |
0..255 |
Loc decoder protocol
settings. |
bit 0 |
Unknown, default 0. |
bit 1 |
Unknown, default 0. |
bit 2 |
Unknown, default: 1. |
bit 3 |
Unknown, default: 0. |
bit 4 |
0: Do not touch Loc
Special Option 4. |
1*: Set Loc Special Option 4 of every new
Märklin/Motorola loc decoder to 1. |
54..79 |
- |
- |
Unknown. |
Lokmaus 1 loc address (calculation) |
80 |
Loc 8 |
0..127 |
Offset value of address
of loc 8 of Lokmaus 1. |
8* |
Default |
81 |
Loc 8 |
0..78 |
Segment value of address
of loc 8 of Lokmaus 1. |
0* |
Default |
82 |
Loc 1 |
0..127 |
Offset value of address
of loc 1 of Lokmaus 1. |
1* |
Default |
83 |
Loc 1 |
0..78 |
Segment value of address
of loc 1 of Lokmaus 1. |
0* |
Default |
84 |
Loc 2 |
0..127 |
Offset value of address
of loc 2 of Lokmaus 1. |
2* |
Default |
85 |
Loc 2 |
0..78 |
Segment value of address
of loc 2 of Lokmaus 1. |
0* |
Default |
86 |
Loc 3 |
0..127 |
Offset value of address
of loc 3 of Lokmaus 1. |
3* |
Default |
87 |
Loc 3 |
0..78 |
Segment value of address
of loc 3 of Lokmaus 1. |
0* |
Default |
88 |
Loc 4 |
0..127 |
Offset value of address
of loc 4 of Lokmaus 1. |
4* |
Default |
89 |
Loc 4 |
0..78 |
Segment value of address
of loc 4 of Lokmaus 1. |
0* |
Default |
90 |
Loc 5 |
0..127 |
Offset value of address
of loc 5 of Lokmaus 1. |
5* |
Default |
91 |
Loc 5 |
0..78 |
Segment value of address
of loc 5 of Lokmaus 1. |
0* |
Default |
92 |
Loc 6 |
0..127 |
Offset value of address
of loc 6 of Lokmaus 1. |
6* |
Default |
93 |
Loc 6 |
0..78 |
Segment value of address
of loc 6 of Lokmaus 1. |
0* |
Default |
94 |
Loc 7 |
0..127 |
Offset value of address
of loc 7 of Lokmaus 1. |
7* |
Default |
95 |
Loc 7 |
0..78 |
Segment value of address
of loc 7 of Lokmaus 1. |
0* |
Default |
96 |
- |
- |
Unknown. |
97 |
Startup mode |
0 |
Startup in 'stop' state. |
1* |
Startup in 'go' state. |
98..203 |
- |
- |
Unknown. |
204 |
DCC decoder programming |
0..255 |
Search address. |
40* |
Recommended value,
especially with new Arnold decoders. |
205..210 |
- |
- |
Unknown. |
211 |
DCC decoder programming |
0..255 |
Search address. |
2* |
Recommended value,
especially with new Arnold Decoders. |
212..223 |
- |
- |
Unknown. |
224 |
DCC decoder programming |
0..255 |
Read Register. |
8* |
Default value. |
10 |
Recommended value when
experiencing programming problems (may also be somewhat higher, e.g. 12). |
225..243 |
- |
- |
Unknown. |
244 |
DCC decoder programming |
0..255 |
Query address (register
mode). |
6* |
Default |
8 |
Recommended value when
experiencing programming problems (may also be somewhat higher, e.g. 10). |
245..256 |
- |
- |
Unknown. |
257 |
DCC decoder programming |
0 |
Disable page preset before register
read. |
1* |
Enable page preset before
register read. |
258..263 |
- |
- |
Unknown. |
264 |
DCC decoder programming |
0..255 |
Write Register. |
10* |
Default |
12 |
Recommended value when
experiencing programming problems (may also be somewhat higher, e.g. 14). |
265..276 |
- |
- |
Unknown. |
277 |
DCC decoder programming |
0* |
Disable page preset before register
write. |
1 |
Enable page preset before
register write. |
278..283 |
- |
- |
Unknown. |
284 |
DCC decoder programming |
0..255 |
Paged read. |
6* |
Default |
8 |
Recommended value when
experiencing programming problems (may also be somewhat higher, e.g. 10). |
285..303 |
- |
- |
Unknown. |
304 |
DCC decoder programming |
0..255 |
Paged write. |
8* |
Default |
10 |
Recommended value when
experiencing programming problems (may also be somewhat higher, e.g. 12). |
305..323 |
- |
- |
Unknown. |
324 |
DCC decoder programming |
0..255 |
Direct byte read. |
6* |
Default |
8 |
Recommended value when
experiencing programming problems (may also be somewhat higher, e.g. 10). |
325..343 |
- |
- |
Unknown. |
344 |
DCC decoder programming |
0..255 |
Direct byte write and
direct bit write. |
8* |
Default |
10 |
Recommended value when
experiencing programming problems (may also be somewhat higher, e.g. 12). |
345..363 |
- |
- |
Unknown. |
364 |
DCC decoder programming |
0..255 |
Direct bit read. |
10* |
Default |
12 |
Recommended value when
experiencing programming problems (may also be somewhat higher, e.g. 14). |
365..394 |
- |
- |
Unknown. |
395 |
Uhlenbrock
decoder
programming |
0* |
Turn off the lights of Uhlenbrock
decoders during programming, except blinking to indicate result of
programming. |
1 |
Do not control the
lights. |
396 |
- |
- |
Unknown. |
397 |
Uhlenbrock
decoder
programming |
24..80 |
Maximum time in units of
250 ms for an Uhlenbrock loc decoder to switch from normal mode to
programming mode. |
50* |
Default: 12.5 secs. |
80 |
Recommended setting (20
secs). |
398 |
Uhlenbrock
decoder
programming |
12..40 |
Maximum time in units of
250 ms which an Uhlenbrock decoder requires to show 4 blinks of the lights
after succesfully processing a programming command, to indicate it is
prepared to receive the expected parameter. |
20* |
Default: 5 secs. |
40 |
Recommended setting (10
secs). |
399 |
Uhlenbrock
decoder
programming |
1..20 |
Minimum time in units of 250 ms for
an Uhlenbrock decoder to accept a new parameter. |
4* |
Default: 1 sec. |
400..449 |
- |
- |
Unknown. |
450 |
Memory mode |
2..100 |
Stepping speed of a
programmed route in units of 50 ms. |
10* |
Default: 0.5 seconds per
step. |
451 |
Memory mode |
1..200 |
Duration of a pause step
in a programmed route in units of 50 ms. |
20* |
Default: 1 second. |
452..454 |
- |
- |
Unknown. |
455 |
Lenz decoder programming |
0..191 |
Unknown. |
51* |
Default |
63 |
May improve programming
of Lenz decoders, like LE0521D,1024/1025. |
456..475 |
- |
- |
Unknown. |
476 |
Short
circuit
detection |
1..15 |
Unit of time for second
'short-circuit' signalling (see SO#478). This value, expressed in units of 50
msecs, divided by the value of SO#477 determines the time after which a
second short-circuit is signalled. |
10* |
Default. With the default
of SO#477, will result in 250 msecs (10 * 50 / 2). |
477 |
Short
circuit
detection |
1..10 |
Factor for second short-circuit
detection (see SO#476). |
2* |
Default |
478 |
Short
circuit
detection |
0 |
Disable second short circuit
detection (see also SO#476 and SO#477). |
4* |
Enable second short
circuit detection. |
This is a fail safe feature in addition to the
primary short circuit detection (controlled with SO#930). |
479 |
Power-on
behaviour |
0..100 |
Number of times - with 3
msec intervals - to check for an (illegal) external voltage. If detected the
Intellibox starts-up in Power-Off mode. |
15* |
Default |
480..495 |
- |
- |
Unknown. |
496 |
External
voltage
detection |
1..100 |
Number of times an external voltage
has to be detected before signalling this error condition. |
3* |
Default |
497 |
External
voltage
detection |
1..250 |
Interval in units of 1 msecs between
external voltage detections. |
100* |
Default: 0.1 secs. |
498 |
Booster control |
0 |
Signal line 'SGNL' always
low. |
1* |
Signal line active:
booster is informed about Power-Off state. |
499..661 |
- |
- |
Unknown. |
662 |
Loc decoder programming |
bit 0 |
0 - Do not set bit 5 of
CV 29 when reading a long address. |
1* - set bit 5 of CV 29 when reading a
long address. |
bit 1 |
0 - bit 5 of CV 29 is not
set when writing a
long address. |
1* - bit 5 of CV 29 is set when writing a
long address. |
bit 2 |
0* - Ignore errors when
writing bit 5 of CV 29 as part of reading or writing a long address. |
1 - do not ignore errors when writing bit 5 of CV 29. |
This does not apply to a bit write
performed through the CV(bit) menu. |
3* |
Default: bit0=1 bit1=1,
bit2=0. |
See also version 1.300 updates in file
'changes.txt' of the update package. |
663 |
IntelliBox reset |
0* |
Disable Intellibox resets
by P50X commands. |
1 |
Do not filter P50X
commands which can result in a reset of the IB. |
664..698 |
- |
- |
Unknown. |
IRIS mode |
699 |
IRIS mode |
0..200 |
Time in units of 150 ms
for the Intellibox panel display in IRIS_mode to revert to showing loc speed
after having shown turnout status. |
0 |
No timeout: no automatic
fall back to loc speed/direction display. |
33* |
Default: approx. 5
seconds. |
700 |
IRIS key |
0..255 |
Command code for IRIS key
'0'. |
0* |
Default |
701 |
IRIS key |
0..255 |
Command code for IRIS key
'1'. |
1* |
Default |
702 |
IRIS key |
0..255 |
Command code for IRIS key
'2'. |
2* |
Default |
703 |
IRIS key |
0..255 |
Command code for IRIS key
'3'. |
3* |
Default |
704 |
IRIS key |
0..255 |
Command code for IRIS key
'4'. |
4* |
Default |
705 |
IRIS key |
0..255 |
Command code for IRIS key
'5'. |
5* |
Default |
706 |
IRIS key |
0..255 |
Command code for IRIS key
'6'. |
6* |
Default |
707 |
IRIS key |
0..255 |
Command code for IRIS key
'7'. |
7* |
Default |
708 |
IRIS key |
0..255 |
Command code for IRIS key
'8'. |
8* |
Default |
709 |
IRIS key |
0..255 |
Command code for IRIS key
'9'. |
9* |
Default |
710..711 |
- |
- |
Unknown. |
712 |
IRIS key |
0..255 |
Command code for IRIS key
'Stop'. |
12* |
Default: toggle Power
Off/On. |
713 |
IRIS key |
0..255 |
Command code for IRIS key
'Loco'. |
14* |
Default: Select Loc
address. |
714 |
IRIS key |
0..255 |
Command code for IRIS key
'Turnout'. |
15* |
Default: Select Turnout
address. |
715 |
IRIS key |
0..255 |
Command code for IRIS key
'Route'. |
16* |
Default: Select Route
number. |
716 |
IRIS key |
0..255 |
Command code for IRIS key
'-->'. |
54* |
Default: direction
forward / emergency stop. |
717 |
IRIS key |
0..255 |
Command code for IRIS key
'<--'. |
55* |
Default: direction
backward, emergency stop. |
718 |
- |
- |
Unknown. |
719 |
IRIS key |
0..255 |
Command code for IRIS key
'Off'. |
107* |
Default: Function (F0) ON
while pressed, then OFF. |
720 |
IRIS key |
0..255 |
Command code for IRIS key
'f0'. |
57* |
Default: Function (F0)
ON. |
721 |
IRIS key |
0..255 |
Command code for IRIS key
'f1'. |
91* |
Default: Toggle Function
F1 (or F5,F9,F13). |
722 |
IRIS key |
0..255 |
Command code for IRIS key
'f2'. |
92* |
Default: Toggle Function
F2 (or F6,F10,F14). |
723 |
IRIS key |
0..255 |
Command code for IRIS key
'f3'. |
93* |
Default: Toggle Function
F3 (or F7,F11,F15). |
724 |
IRIS key |
0..255 |
Command code for IRIS key
'f4'. |
94* |
Default: Toggle Function
F4 (or F8,F12,F16). |
725..728 |
- |
- |
Unknown. |
729 |
IRIS key |
0..255 |
Command code for IRIS key
'f+4'. |
20* |
Default: Shift key f1..4
to f5..f8. |
730 |
IRIS key |
0..255 |
Command code for IRIS key
'f+8'. |
21* |
Default: Shift key f1..4
to f9..f12. |
731 |
- |
- |
Unknown. |
732 |
IRIS key |
0..255 |
Command code for IRIS key
'+'. |
24* |
Default: Increase speed. |
733 |
IRIS key |
0..255 |
Command code for IRIS key
'-'. |
25* |
Default: Decrease speed. |
734..739 |
- |
- |
Unknown. |
740 |
IRIS key |
0..255 |
Command code for IRIS key
'T0 red'. |
124* |
Default: Turnout
base_address + 0: RED. |
741 |
IRIS key |
0..255 |
Command code for IRIS key
'T0 green'. |
125* |
Default: Turnout
base_address + 0: GREEN. |
742 |
IRIS key |
0..255 |
Command code for IRIS key
'T1 red'. |
126* |
Default: Turnout
base_address + 1: RED. |
743 |
IRIS key |
0..255 |
Command code for IRIS key
'T1 green'. |
127* |
Default: Turnout
base_address + 1: GREEN. |
744 |
IRIS key |
0..255 |
Command code for IRIS key
'T2 red'. |
128* |
Default: Turnout
base_address + 2: RED. |
745 |
IRIS key |
0..255 |
Command code for IRIS key
'T2 green'. |
129* |
Default: Turnout
base_address + 2: GREEN. |
746 |
IRIS key |
0..255 |
Command code for IRIS key
'T3 red'. |
130* |
Default: Turnout
base_address + 3: RED. |
747 |
IRIS key |
0..255 |
Command code for IRIS key
'T3 green'. |
131* |
Default: Turnout
base_address + 3: GREEN. |
748..767 |
- |
- |
Unknown. |
768 |
IRIS to PC |
0..15 |
Select IRIS commands to
be forwarded to PC. |
bit 0 |
0 = Do not forward, 1 =
Forward commands not coming from an IRIS channel. |
bit 1 |
0 = Do not forward, 1 =
Forward P50X commands (see docs). |
bit 2 |
0 = Do not forward, 1 =
Forward commands coming from an IRIS channel. |
bit 3 |
0 = Do not forward, 1 =
Forward LocoNet commands (see docs). |
1* |
Forward P50X commands. |
769 |
Speed steps |
1..13 |
Number of speed steps of
controlled loc to jump with the '+' or '-' keys. |
4* |
Default |
770 |
IRIS key |
0..200 |
Timeout in units of 0.15
seconds for Loco/Turnout/Route and Function keys. |
67* |
Default: approx. 1
second. |
771 |
IRIS key |
0..255 |
Command to be executed
when the 'f1' key is pressed after pressing the 'f+4' key. |
95* |
Default: toggle the F5
function. |
772 |
IRIS key |
0..255 |
Command to be executed
when the 'f2' key is pressed after pressing the 'f+4' key. |
96* |
Default: toggle the F6
function. |
773 |
IRIS key |
0..255 |
Command to be executed
when the 'f3' key is pressed after pressing the 'f+4' key. |
97* |
Default: toggle the F7
function. |
774 |
IRIS key |
0..255 |
Command to be executed
when the 'f4' key is pressed after pressing the 'f+4' key. |
98* |
Default: toggle the F8
function. |
775 |
IRIS key |
0..255 |
Command to be executed
when the 'f1' key is pressed after pressing the 'f+8' key. |
99* |
Default: toggle the F9
function. |
776 |
IRIS key |
0..255 |
Command to be executed
when the 'f2' key is pressed after pressing the 'f+8' key. |
100* |
Default: toggle the F10
function. |
777 |
IRIS key |
0..255 |
Command to be executed
when the 'f3' key is pressed after pressing the 'f+8' key. |
101* |
Default: toggle the F11
function. |
778 |
IRIS key |
0..255 |
Command to be executed
when the 'f4' key is pressed after pressing the 'f+8' key. |
102* |
Default: toggle the F12
function. |
779 |
IRIS key
debounce |
2..21 |
Mimimum time in units of
150 ms that an IRIS key must have been released before taking the appropriate
action. Applies to Function keys. |
2* |
Default: 0.3 seconds. |
780 |
IRIS key command |
10..255* |
Command to be executed
when the '0' key is pressed when not entering an address or number sequence. |
255* |
Default: no action. |
781 |
IRIS key command |
10..255* |
Command to be executed
when the '1' key is pressed when not entering an address or number sequence. |
255* |
Default: no action. |
782 |
IRIS key command |
10..255* |
Command to be executed
when the '2' key is pressed when not entering an address or number sequence. |
255* |
Default: no action. |
783 |
IRIS key command |
10..255* |
Command to be executed
when the '3' key is pressed when not entering an address or number sequence. |
255* |
Default: no action. |
784 |
IRIS key command |
10..255* |
Command to be executed
when the '4' key is pressed when not entering an address or number sequence. |
255* |
Default: no action. |
785 |
IRIS key command |
10..255* |
Command to be executed
when the '5' key is pressed when not entering an address or number sequence. |
255* |
Default: no action. |
786 |
IRIS key command |
10..255* |
Command to be executed
when the '6' key is pressed when not entering an address or number sequence. |
255* |
Default: no action. |
787 |
IRIS key command |
10..255* |
Command to be executed
when the '7' key is pressed when not entering an address or number sequence. |
255* |
Default: no action. |
788 |
IRIS key command |
10..255* |
Command to be executed
when the '8' key is pressed when not entering an address or number sequence. |
255* |
Default: no action. |
789 |
IRIS key command |
10..255* |
Command to be executed
when the '9' key is pressed when not entering an address or number sequence. |
255* |
Default: no action. |
790 |
IRIS key
debounce |
1..21 |
Mimimum time in units of
150 ms that a '-' or '+' key must be pressed before accepting is as valid. |
3* |
Default: 0.45 seconds. |
791 |
IRIS route control |
0..255* |
Command code for turnout
key T0 red, when pressed immediately after Route key. |
See also SO#715. |
255* |
No action. |
792 |
IRIS route control |
0..255* |
Command code for turnout
key T0 green, when pressed immediately after Route key. |
255* |
No action. |
793 |
IRIS route control |
0..255* |
Command code for turnout
key T1 red, when pressed immediately after Route key. |
255* |
No action. |
794 |
IRIS route control |
0..255* |
Command code for turnout
key T1 green, when pressed immediately after Route key. |
255* |
No action. |
795 |
IRIS route control |
0..255* |
Command code for turnout
key T2 red, when pressed immediately after Route key. |
255* |
No action. |
796 |
IRIS route control |
0..255* |
Command code for turnout
key T2 green, when pressed immediately after Route key. |
255* |
No action. |
797 |
IRIS route control |
0..255* |
Command code for turnout
key T3 red, when pressed immediately after Route key. |
255* |
No action. |
798 |
IRIS route control |
0..255* |
Command code for turnout
key T3 green, when pressed immediately after Route key. |
255* |
No action. |
799 |
Turnout base |
0 |
A common turnout base
address is used for all IRIS channels. |
1* |
Each IRIS channel uses
its own Turnout base address. |
Panel operation |
800 |
display backlight |
0..13* |
Backlight level of Intellibox panel
display. |
801 |
display contrast |
0*..100 |
Contrast voltage level of
Intellibox panel display. |
(0 = 0V, 100 = 5V). |
802 |
LED dimming |
0..6 |
Dimming factor of LEDs |
(higher value gived reduced brightness). |
4* |
Medium brightness. |
803 |
display language |
0..8 |
Language of messages on
Intellibox panel display. |
P50Xa protocol replies are always in
English. |
0* |
German |
1 |
English |
2 |
French |
3 |
Italian |
4 |
Dutch |
5 |
Swedish |
6 |
Spanish |
7 |
Portugese |
8 |
Danish |
804..807 |
- |
- |
Unknown. |
808 |
Loc
direction
control |
0* |
AC style speed control: direction
switching by push-button. |
1 |
DC style automatic
direction switching. |
809 |
Speed
indication |
0* |
Absolute step value
(protocol dependent). |
1 |
Percentage of maximum
speed. |
810 |
Turnout
selection |
0 |
When in keyboard mode
each red/green key pair is assigned an address from the keyboard table
(SO#871..878). |
1*..255 |
Address of turnout
assigned to key pair '1'(red) and '4'(green) when in keyboard mode. |
The following 7 addresses are assigned to
subsequent pairs of red/green keys. |
811 |
- |
- |
Unknown. |
812 |
Sensor display |
1*..128 |
Sequence number of the group of 8
sensor bits (half S88) to be displayed on the Intellibox panel display initially after
power-on or reset. |
813..814 |
- |
- |
Unknown. |
815 |
Turnout
selection |
0..4 |
Initial 'mode' setting of
the Intellibox panel display after power on or reset. |
The value of this SO is 1 lower than the number
of the key to press after the 'mode' key. |
0* |
Keyboard mode. |
1 |
Memory mode. |
2 |
S88 monitor mode. |
3 |
Programming mode. |
4 |
IRIS mode. |
|
When 'memory mode' option
is not installed (in older Intelliboxes), the numbering is:
0=Keyboard mode, 1=S88 Monitor mode, 2=Programming mode. |
816 |
- |
- |
Unknown. |
817 |
Mode
change
display |
1..255 |
Time in units of 10 ms during which
mode change message is being displayed after hitting the 'mode' key. |
100* |
Default (1 second). |
818..821 |
- |
- |
Unknown. |
822 |
Decoder programming |
75..255 |
Unknown. |
100* |
Default. A value of 75 or
150 may be needed to display the correct speed and format values after
upgrading to version 1.500 or 1.501. |
823..824 |
- |
- |
Unknown. |
825 |
Decoder programming |
0*..1 |
Unknown. |
1 |
May improve reliability
of determining address of older DCC decoders, like Märklin 6085. |
826 |
Decoder programming |
0..4 |
Default menu when
entering programming mode. |
0* |
Uhlenbrock decoder menu. |
1 |
DCC decoder menu. |
2 |
Selectrix decoder menu. |
3..4 |
Unknown. |
827 |
Startup mode |
0 |
No questions (see with
value 1). |
1* |
Intellibox asks if locs
really have to start at the previously saved speed. |
828..834 |
- |
- |
Unknown. |
835 |
Speed of
consists |
0 |
Show speed of a consists
in speed steps. |
1* |
Show speed of consists in
percentage of maximum speed. |
836 |
Loc
decoder
programming |
0* |
Do not display sub-menu with decoder
address search option. |
1 |
Display sub-menu of
decoder address search option. |
837 |
Loc mode after restart |
0* |
No locs are preselected after restart |
1 |
The locs, which are selected before the last power off are
displayed after the restart |
2..4 |
For each IB-Control, which must have this behavior, increase the
value one incremet. Max. 3 IB-Controls |
838 |
IRIS mode |
0 |
Disable IRIS mode
(automatically set to 1 by the Intellibox upon receiving an IR command). |
Note: Requires
power off/on of the Intellibox after any change. |
1* |
Enable IRIS mode. |
839 |
IRIS mode |
0..200 |
Time in units of 100 ms
of the Intellibox panel display in IRIS_mode to revert to showing loc speed
after having shown loc function status. |
0 |
No timeout: no automatic
fall back to speed/direction display. |
25* |
Default: 2.5 seconds. |
840 |
Rotary
encoder
control |
0* |
Rotary encoders behave normally with
respect to the control of locomotive speed and direction. |
1 |
Pressing the rotary
encoder either stops the locomotive (immediately) and, if the rotary encoders
have been configured for 'AC mode', inverts the locomotive driving direction. |
841..843 |
- |
- |
Unknown. |
844 |
IB
mode |
0* |
The IB works as central |
1 |
The IB works as IB-Control (e.g. an additional control unit
operated together with a second Intellibox) |
845..860 |
- |
- |
Unknown. |
Lokmaus key table |
861 |
Loc 1 |
1*..4 |
With each Lokmaus right
button press: toggle F1..F4 on/off. |
5..8 |
Lokmaus right button
pressed: F1..F4 on, released: F1..F4 off. |
9..12 |
As values 1..4. |
In addition: Lokmaus left button pressed:
FL/function on, released: FL/function off. |
13..16 |
As values 5..8. |
In addition: Lokmaus left button pressed:
FL/function on, released: FL/function off. |
862 |
Loc 2 |
1*..4 |
With each Lokmaus right
button press: toggle F1..F4 on/off. |
5..8 |
Lokmaus button right
pressed: F1..F4 on, released: F1..F4 off. |
9..12 |
As values 1..4. |
In addition: Lokmaus left button pressed:
FL/function on, released: FL/function off. |
13..16 |
As values 5..8. |
In addition: Lokmaus left button pressed:
FL/function on, released: FL/function off. |
863 |
Loc 3 |
1*..4 |
With each Lokmaus right
button press: toggle F1..F4 on/off. |
5..8 |
Lokmaus right button
pressed: F1..F4 on, released: F1..F4 off. |
9..12 |
As values 1..4. |
In addition: Lokmaus left button pressed:
FL/function on, released: FL/function off. |
13..16 |
As values 5..8. |
In addition: Lokmaus left button pressed:
FL/function on, released: FL/function off. |
864 |
Loc 4 |
1*..4 |
With each Lokmaus right
button press: toggle F1..F4 on/off. |
5..8 |
Lokmaus right button
pressed: F1..F4 on, released: F1..F4 off. |
9..12 |
As values 1..4. |
In addition: left Lokmaus button pressed:
FL/function on, released: FL/function off. |
13..16 |
As values 5..8. |
In addition: left Lokmaus button pressed:
FL/function on, released: FL/function off. |
865 |
Loc 5 |
1*..4 |
With each Lokmaus right
button press: toggle F1..F4 on/off. |
5..8 |
Lokmaus right button
pressed: F1..F4 on, released: F1..F4 off. |
9..12 |
As values 1..4. |
In addition: Lokmaus left button pressed:
FL/function on, released: FL/function off. |
13..16 |
As values 5..8. |
In addition: Lokmaus left button pressed:
FL/function on, released: FL/function off. |
866 |
Loc 6 |
1*..4 |
With each Lokmaus right
button press: toggle F1..F4 on/off. |
5..8 |
Lokmaus right button
pressed: F1..F4 on, released: F1..F4 off. |
9..12 |
As values 1..4. |
In addition: Lokmaus left button pressed:
FL/function on, released: FL/function off. |
13..16 |
As values 5..8. |
In addition: Lokmaus left button pressed:
FL/function on, released: FL/function off. |
867 |
Loc 7 |
1*..4 |
With each Lokmaus right
button press: toggle F1..F4 on/off. |
5..8 |
Lokmaus right button
pressed: F1..F4 on, released: F1..F4 off. |
9..12 |
As values 1..4. |
In addition: Lokmaus left button pressed:
FL/function on, released: FL/function off. |
13..16 |
As values 5..8. |
In addition: Lokmaus left button pressed:
FL/function on, released: FL/function off. |
868 |
Loc 8 |
1*..4 |
With each Lokmaus right
button press: toggle F1..F4 on/off. |
5..8 |
Lokmaus right button
pressed: F1..F4 on, released: F1..F4 off. |
9..12 |
As values 1..4. |
In addition: Lokmaus left button pressed:
FL/function on, released: FL/function off. |
13..16 |
As values 5..8. |
In addition: Lokmaus left button pressed:
FL/function on, released: FL/function off. |
869..870 |
- |
- |
Unknown. |
Turnout key table |
871 |
Turnout 1 |
0..255 |
Address less 1 of turnout
to be assigned to key pair 1(red),4(green). |
10* |
Turnout 11 assigned to
key pair (1,4). |
872 |
Turnout 2 |
0..255 |
Address less 1 of turnout
to be assigned to key pair 2(red),5(green). |
20* |
Turnout 21 assigned to
key pair (2,5). |
873 |
Turnout 3 |
0..255 |
Address less 1 of turnout
to be assigned to key pair 3(red),6(green). |
30* |
Turnout 31 assigned to
key pair (3,6). |
874 |
Turnout 4 |
0..255 |
Address less 1 of turnout
to be assigned to key pair C(red),+(green). |
40* |
Turnout 41 assigned to
key pair (C,+). |
875 |
Turnout 5 |
0..255 |
Address less 1 of turnout
to be assigned to key pair 7(red),left-arrow(green). |
50* |
Turnout 51 assigned to
key pair (7,left-arrow). |
876 |
Turnout 6 |
0..255 |
Address less 1 of turnout
to be assigned to key pair 8(red),0(green). |
60* |
Turnout 61 assigned to
key pair (8,0). |
877 |
Turnout 7 |
0..255 |
Address less 1 of turnout
to be assigned to key pair 9(red),right-arrow(green). |
70* |
Turnout 71 assigned to
key pair (9,right-arrow). |
878 |
Turnout 8 |
0..255 |
Address less 1 of turnout
to be assigned to key pair Enter(red),down-arrow(green). |
80* |
Turnout 81 assigned to
key pair (Enter,down-arrow). |
879..900 |
- |
- |
Unknown. |
Miscellaneous |
901 |
booster
signal
control |
1*..100 |
Asymmetry factor of digital signal on
booster connection. |
3 |
When Märklin boosters
6015 or 6017 are used to control DCC decoders. |
902 |
Function
decoder
control |
12 |
Default |
16 |
(up to about 18) to
correct failing command transmission to the Märklin measurement car and
crane. |
903 |
- |
- |
Unknown. |
904 |
- |
2..255 |
? |
28* |
Default. |
42 |
Recommended value when
older DCC decoders are used together with Motorola decoders. |
905..906 |
- |
- |
Unknown. |
907 |
idle signal |
1* |
Motorola idle signal is
sent until the first Motorola loc is addressed. |
When SO#25 is '1' the idle signal will be
remain to be sent even after the first Motorola loc has been addressed. |
4 |
A DCC idle signal is
sent. |
5 |
Both Motorola and DCC
idle signals are sent. |
908 |
Short
Circuit
Control |
0..255 |
Reaction time to a short-circuit
condition reported by an external Booster. |
3 |
Default. |
909 |
- |
193..202 |
Controls the time between
a Marklin/Motorola and a successive DCC frame. |
198* |
Default: approx. 0.9
microseconds. |
199 |
or slightly higher
ensures Märklin C95 decoders (6095) behave correctly. |
May also apply to Delta decoders and 'special'
6090 decoders with the 701.17 chip. |
202 |
Maximum: approx. 2.1
microseconds. |
910..913 |
- |
- |
Unknown. |
914 |
Function
decoder
control |
18* |
Default |
24 |
(up to about 26) to
correct failing command transmission to the Märklin measurement car. |
40 |
to control the Märklin
crane (46715). |
915..929 |
- |
- |
Unknown. |
930 |
Short
Circuit
control |
10..120 |
Time in units of 5 ms before power
shut-off after detection of excessive current flow. |
100* |
Default (0.5 seconds). |
931 |
Stop waittime |
0..255 |
Time in units of 7 µs to
wait for the I2C Stop signal. |
1* |
For Märklin Control Unit
6021 and/or a Märklin keyboard 6040 attachments. |
Default for SPU versions 1.007 and higher. |
2..3 |
Alternatives for 1. |
Value 2 is default for SPU version 1.000. |
5 |
When Märklin 6027 or
another DCC CU is connected. |
Default setting for SPU versions 1.001 to
1.006. |
932 |
Bit length |
0..255 |
Length of a bit in units
of 4 µs. |
4* |
Default: 16 µs. |
933..934 |
- |
- |
Unknown. |
935 |
I2C pause |
0..255 |
High nibble (high order
half byte) determines pause in ms after first byte of a (2-byte) I2C command
to a C80(f) or keyboard. |
Low nibble (low order half byte) determines
pause in ms after last byte of an I2C message. |
17* |
Default (hexadecimal
'11'): 1 ms pause for both situations. |
936..998 |
- |
- |
Unknown. |
999 |
Firmware |
fixed |
High order digits of
firmware version number. |
|
|
|
|